Metal roofing from georgia metals is higher quality but not necessarily higher priced.
Ga rib metal roof installation instructions.
This guide is supplied by fabral inc.
We strive to offer equal or even lower prices than competitors.
It is extremely important that this panel be laid square to the eave and ridge so that the remaining panels will line up square on the roof frame.
For use by its customers and is intended to be a guide only.
That said please beware when shopping for your metal roofing project sometimes a lower price may indicate a lower quality such as a thinner metal lower yield strength or an inferior paint.
Install eave trim valley trim and inside closure prior study the details section of this manual prior to the to panel installation.
5 rib roofing panels must be applied on a minimum roof pitch of 2 12 or greater.
Panel installation light gauge metal roof and wall panels installation guide for delta rib delta rib iii nor clad strata rib 2 corrugated panel installation procedure general 1.
This guide must by read in its entirety before beginning installation.
The installation of metal roof systems is a dangerous procedure and should be supervised by trained knowl.
Available in the following metal roofing and siding.
24 ga optional 36 panel coverage 3 4 rib height.
Place sealant over underlap rib before sliding hem over the eave trim.
At this point chalk a line from ridge to eave.
12 16 skyline roofing 26 gauge.
36 nor clad 29 gauge.
3 5 rib installation guidelines caution.
Another option is to install a or 7 8 lap stitch screw in the crown of the rib to secure the side lap.
25 years limited lifetime.
Install the panel a minimum of 3 up from the water diverter at the bottom of the valley and minimum of 3 down from the top of the valley.
Install the roof substrate according to local building code requirements.
Install the roofing screws vertically along each rib in the panel.
Measure one panel width in from the roof edge.
Place the leading edge of the first panel along this line.
See panel squaring method in this manual.
Snap first two to three inches of panel together and slide the panel tight against the eave trim or with the gap depending on the temperature.
29 ga and 26 ga standard.
Preformed valley trim panel wood screw tuff rib panel.
Align the first metal roofing panel so that it overlaps the edging by 1 2 to 3 4 of an inch and is square to the roof line.
36 delta rib iii 29 gauge.
Butyl tape as shown below is recommended along panel side laps.
Be sure the larger edge is laid so that the small edge of the next panel will overlap it.
36 strata rib 29 gauge.
Install screws every 6 10 inches.